Jockey Pump Controller Parts

Jockey Pump Controller Parts

Items: 17 of 7, per page



    OEM 4-20mA Pressure Sensor (0-600 PSI) LMR Plus Fire Pump Controllers

    Includes Transducer (P/N 4A55678H01) & Bulkhead Fitting (P/N 4A55537H01)

    Replaces Obsolete 4A55678H01, 4A55511H01, 4A55511H02 and 4A55535H01

    Typically Ships in 1-2 Days

    • $513.00



    Replacement bulkhead fitting for fire pump and jockey pump pressure transducers and pressure switches.

    1/2" thread, includes pass-through bushing, lock washer, and lock nut. 


    Eaton P/N 4A55537H01 

    • $13.71

    Specifically formatted for use with Eaton Cutler-Hammer Fire Pump Controllers.

    This USB drive is compatible with Firetrol and other fire pump controllers which have USB memory drives, including older models in which other thumb drives may not work in.

    2GB

    In stock

    • $8.75


    Replacement Jockey Pump Controller Pressure Switch

    The Alco Controls Series PS-1-X4A (PCN) 4715704) (466335-0001) (099025) pressure switch was furnished as standard in various manufacturer's jockey pump controllers including Eaton Cutler-Hammer, Firetrol, Patterson and Joslyn Clark. (Although not all jockey pump controllers furnished by these manufacturers use this switch, verify the acceptability of this switch as a replacement for other styles.)

    • Adjustable cut-out of 15 to 290 PSI with differential of 15 to 120 PSI. - Model PS1-X4A
    • Connections on pressure switch 7/16"-20 UNF for 1/4" SAE male flare connection. 


    In Stock! Ships in 1-2 business days. 


    WE HIGHLY RECOMMEND THE OPTIONAL ADAPTER!
    This could save hours in the field. The pressure switch is often difficult to spin inside the controllers which means without the adapters you may have to cut the sensing line and re-solder new copper.

    • $219.95

    Replacement Jockey Pump Controller Pressure Switch

    The Alco Controls Series PS-1-X5A (PCN 099026) pressure switch was furnished as standard in various manufacturer's jockey pump controllers including Eaton Cutler-Hammer, Firetrol and Joslyn Clark. This style switch was not used in all jockey pump controllers furnished by these manufacturers and it is necessary to verify the acceptability of using this switch as a replacement for other styles. These switches should only be used in three phase jockey pump controllers which are provided with a control transformer or which are single phase voltage controllers. 

    Adjustable cut-out of 90 to 450 PSI with differential of 30 to 220 PSI. - Model PS1-X5A

    Manufacturers that have used this pressure switch*;

    • Eaton Cutler-Hammer
    • Firetrol (AKA PS-1134)
    • Joslyn Clark

    *Not all of the jockey pump controllers by these manufacturers use this pressure switch. You can confirm by looking inside the controller and verifying the model number of the actual pressure switch itself. You may also contact us with model number, serial number and manufacturer of the controller and we will attempt to determine the acceptability of the replacement pressure switch.

    Connections on pressure switch 7/16"-20 UNF for 1/4" SAE male flare connection. 

    If this is not a direct replacement for an identical model Alco switch additional fittings may be required for installation so as to provide NPT threads. Optional tube adapter fittings are available.

     

    Typically in stock and ships in 1-2 business days.

     

    • $262.95


    Replacement Jockey Pump Controller Pressure Switch

    The Alco Controls Series FF444-V4 DAF (PCN0097311) pressure switch was furnished as standard in various manufacturer's jockey pump controllers including Metron and Joslyn Clark. This style switch was not used in all jockey pump controllers furnished by these manufacturers and it is necessary to verify the acceptability of using this switch as a replacement for other styles. These switches should only be used in three phase jockey pump controllers which are provided with a control transformer or which are single phase voltage controllers. 

    Lower Switch Point Range - 6-217 psig
    Upper Switch Point Range - 15-232 psig
    Smallest Differential @ Lower-Higher end of Rainge - 9-14 psig
    Standard Settings - 58/174 psig

    Manufacturers that have used this pressure switch*;

    • Metron
    • Joslyn Clark A022-354574

    *Not all of the jockey pump controllers by these manufacturers use this pressure switch. You can confirm by looking inside the controller and verifying the model number of the actual pressure switch itself. You may also contact us with model number, serial number and manufacturer of the controller and we will attempt to determine the acceptability of the replacement pressure switch.

    Connections on pressure switch 1/4" NPTF

     

    Typically in stock and ships in 1-2 business days.

     

    • $485.00

    7/16"-20 UNF for 1/4" SAE to 1/4" NPT Adapter  

    Connections on pressure switch 7/16"-20 UNF for 1/4" SAE male flare connection. This adapter will allow you to use Alco PS1 pressure switches and other similar switches with pipe thread.

    • $37.95